11
Cable
ES-200
Dual Channel
Desk Station
E-200 Series
Power requirements:
12-32V, nom. 24V/ 70 mA.
Connections:
2x Intercom Line XLR-
3M/XLR-3F per channel.
Remote functions:
Mic kill, Buzzer kill. Mic-
speaker activation.
Dimensions and Weight:
2U X 19" | 310X89X70 mm
1,6 Kg. net.
Specifications
Remote Desk Station
The ES-200 can be mounted as an angled
position desk station or rack and flush mounted
using the included ears. The unit allows full
duplex hands-free communication with both
channels and is powered remotely from the
intercom system.
Permanent gooseneck panel microphone and
internal loudspeaker optimised for voice
communication allows clear communications
in moderate noisy environments.
The headset connection disables automatically the mic and the speaker when privacy is needed.
Besides the normal intercom applications, the unit features a remote message function as well as a Mic-On-Remote function
both remotely controlled by the Master station.
This unit is a complement of the EF-200 master station when the panel mic and speaker listening are a must.
Key Features
• Internal loudspeaker and gooseneck microphone
• Automatic disconnection of the mic-speaker when headset is used
• Mic latched or PTT –push to talk-logic function
• Remote mic and buzzer kill functions
• High buzzer sounding with volume control
• Microphone limiter easing comfortable communications
• Feedback controls on the front panel
• Programmable functions: Remote speaker and mic activation.
Universal Interface
4W2-200
Universal
4W/2W
Interface
E-200 Series
Power requirements::
12-32 V, nom. 24V/ 25 mA.
4W Connection:
balanced XLR-4M.
Intercom Line:
XLR-3M.
Telephone line:
Standard RJ-11
Dimensions and Weight:
84X38X140 mm
330 gr net.
Specifications
This single channel unit changes the bidirectional intercom line into one-direction
IN/OUT signals. Wide range mic or line level signals can be accommodated
to/from the intercom system. Output signal from the intercom line is easily
adjustable to adapt for external operation as recording, PA, etc. The unit allows
interfacing to another non compatible intercom signals.
This interface is also useful to connect an entire intercom system to a telephone
line allowing external calls to be shared within the intercom operators.
The unit is especially suitable for interfacing professional CAMS equipped with
CCU to the intercom lines.
Key Features
• Unit is remotely powered from the Master Station.
• Cam interfacing trough CCU connections.
• Telephone line interfacing.
• Interface for non compatible intercom systems.
• Wide range level adjustments.
• IN/OUT are transformer balanced ensuring clean signals and an
improved EMI immunity.
APPLICATION EXAMPLE
PRODUCTION MANAGER
CH-A
CH-B
VIDEO CONTROL
CH-B
4W2-200
CAM OPERATORS
..
..
..
CCU CAM2
CCU CAM1
CAM INTERFACING